Luminor Blackcomb 5.0 UV System:
Looking for a feature-laden premium UV system, then LUMINOR's Blackcomb5.0 line of domestic UV systems should be your choice. In looking at this line, one easily sees how this product is truly different from everything else in the market. Blackcomb's state-of-the-art 5.0 series controller is a constant current electronic power source housed in a splash-proof case and comes standard with a "future-proof" expandability port for future upgrades or options.A colour user interface allows for easy visual identification of remaining lamp life and any error or fault codes.
The system even incorporates QR codes to access lamp change information and videos via web access. Rugged 304 stainless steel, single-end reactors come with an integral port to allow for a future upgrade to a UV monitored system. The single-end design allows for lamp change without the need to drain the reactor chamber. Reliable, industry proven, high quality low pressure (LP) coated UV lamps are used offering a consistent output over their 9,000 hour life. Flow rates of 10, 20, 40, 57 & 80 lpm (3, 6, 10, 15, & 20 gpm), are offered in the Blackcomb 5.0 series of products.
Model |
LB5-033 |
LB5-063 |
LB5-103 |
LB5-153 |
LB5-203 |
Flow Rate
(@ 30mj/cm2) |
11.4 lpm
0.7m3/hr |
22.7lpm
1.4m3/hr |
41 lpm
2.5m3/hr |
57 lpm
3.4m3/hr |
79 lpm
4.8m3/hr |
Port Size |
1/2" MNPT |
3/4" MNPT |
3/4" MNPT |
1" MNPT |
1" MNPT |
Electrical |
90-265 V / 50 - 60 Hz |
Lamp Watts |
15 |
22 |
39 |
50 |
42 |
Power (Watts) |
20 |
30 |
49 |
62 |
51 |
Replacement Lamp |
RL-290 |
RL-470 |
RL-820 |
RL-999 |
RL-850 |
Replacement Sleeve |
RQ-290 |
RQ-470 |
RQ-820 |
RQ-999 |
RQ-850 |
Chamber Material |
304 Stainless Steel, A249 Pressure Rated Tubing, Polished & Passivated |
Reactor Dimensions |
2.5 x 14.3"
(6.4 x 36.4cm) |
2.5 x 21.3"
(6.4 x 54.2cm) |
2.5 x 35.2"
(6.4 x 89.5cm) |
2.5 x 40"
(6.4 x 101.6cm) |
3.5 x 36.1"
(8.9 x 91.7cm) |
Controller Dimensions |
6.8 x 3.6 x 3"
(17.2 x 9.2 x 7.6cm) |
Operating Pressure |
0.7 - 10.3 bar (10 - 150 psi) |
Operating Water Temperature |
2 - 40o (36 - 104o F) |
UV Monitor Port |
No |
Yes (optional UV Sensor module sold separately) |
Solenoid Output |
Yes (requires optional solenoid module) - Activates on lamp failure |
Dry Contacts |
Yes (requires optional remote alarm module) |
4-20mA Output |
Yes (requires optional 4-20mA module) |
Lamp Change Reminder (audio & visual) |
Yes |
Lamp Out Indicator (audio & visual) |
Yes |
Additional information
UV Sensor Module
Allows the 254nm UV wavelength to be measured and displayed via the BLACKCOMB contoller. The sensor plugs directly into the contoller and is mounted in the sensor port located on all BLACKCOMB5.0 or BLACKCOMB6.0 reactors. Order RS-B2.5 for 6, 10 & 15 gpm systems and RS-B3.5 for 20 gpm systems
Solenoid Module
Used to power a remote normally closed solenoid valve (not included). Solenoid will close on lamp failure or when low UV conditions are detected by the sensor. Available in 110V. (MOD-SOL1) or 230V. (MOD-SOL2)
4-20m Module
Used for signal transfer to a remote device such as a data logger or computer. Order MOD-420
Remote Alarm (Dry Contact) Module
Used for signal transfer to a remote alarm or dry contacts. Order MOD-RAM